Evaluation of suspected small bowel ischemia using contrast-enhanced ultrasound with computed tomography fusion


1 Department of Surgery, Thomas Jefferson University, Philadelphia, PA, USA
2 Department of Radiology, Thomas Jefferson University, Philadelphia, PA, USA

Click here for correspondence address and email

Date of Submission20-Apr-2021
Date of Acceptance29-Oct-2021
Date of Web Publication4-Apr-2022
 

   Abstract 


Small bowel ischemia can lead to fatal complications such as necrosis, perforation, and sepsis. Clinical examinations and laboratory tests are usually inconclusive in critically ill patients. The need for surgical exploration is decided based on imaging, examination, and clinical judgment. The decision to operate is time-critical and can be lifesaving, but surgical intervention has the potential to cause additional morbidity, especially in unstable patients. Contrast-enhanced computed tomography (CECT) is the study of choice in suspected small bowel ischemia but has poor specificity. Contrast-enhanced ultrasound (CEUS) provides real-time visualization of the bowel wall vascularity. In this case report, we used a CEUS with CT fusion examination to rule out small bowel ischemia in a critically ill patient with suspected closed loop small bowel obstruction on CECT and in whom surgical exploration would have not been well tolerated. The patient's condition later improved, and an abdominal CT showed no evidence of obstruction.

Keywords: Computed tomography fusion, contrast-enhanced ultrasound, small bowel ischemia

How to cite this article:
Koenig G, Tantawi M, Wessner CE, Eisenbrey JR. Evaluation of suspected small bowel ischemia using contrast-enhanced ultrasound with computed tomography fusion. J Emerg Trauma Shock 2022;15:60-2

How to cite this URL:
Koenig G, Tantawi M, Wessner CE, Eisenbrey JR. Evaluation of suspected small bowel ischemia using contrast-enhanced ultrasound with computed tomography fusion. J Emerg Trauma Shock [serial online] 2022 [cited 2022 Jul 5];15:60-2. Available from: https://www.onlinejets.org/text.asp?2022/15/1/60/342512





   Introduction Top


Small bowel ischemia is a potentially fatal complication of common conditions. It can lead to perforation, necrosis, and sepsis. Clinical signs of small bowel ischemia include pain out of proportion to the physical examination, nausea, vomiting, and fever. In addition, abdominal tenderness, guarding and absent bowel sounds can be detected if the patient develops peritonitis. However, these signs can be absent in many cases. The diagnosis is typically based on contrast-enhanced computed tomography (CECT) alone or in combination with physical examination, and laboratory tests. In patients with ongoing or impending vascular compromise, urgent exploratory laparotomy is indicated to restore blood flow or resect the necrotic bowel. However, impending small bowel ischemia can be a challenging diagnosis in many cases. Modern ultrasound systems allow the reconstruction and integration of prior cross-sectional scans (CT/magnetic resonance imaging [MRI]) with live ultrasound imaging in the same plane.[1] Contrast-enhanced ultrasound (CEUS) fusion requires image registration from different modalities which can be automated, semiautomated, or manual. The scan can be performed by technicians after validating the registration process by examining anatomical landmarks. It is an inexpensive, accessible technology, and can be done at the patient's bedside. This case demonstrates the benefits of CEUS with CT fusion as a rule-out test for small bowel ischemia in a critically ill patient.


   Case Report Top


A 23-year-old female with a 10-year history of Crohn's disease was admitted to the inpatient unit due to intractable abdominal pain. The patient stated that she had suffered from abdominal pain for 3 months and also described night sweats and weight loss of 20–25 lbs. in 1 month. The patient looked thin and frail. Physical examination revealed mild diffuse tenderness in the abdomen, clear chest, and no peripheral adenopathy. Laboratory examination was significant for elevated lipase level (427 U/L). She previously underwent bowel resection for Crohn's disease approximately 10 years ago. Subsequently, her Crohn's disease was managed by immunosuppressive therapy.

On admission, her abdominal CT scan was notable for multiple masses throughout the pancreas which were later diagnosed with diffuse large B-cell lymphoma. Her hospital course was complicated by systemic inflammatory response syndrome, Crohn's colitis, and hemorrhagic shock from bleeding localized to the second part of the duodenum. The patient received several units of packed red blood cells and underwent angioembolization of the proximal branch of the superior mesenteric artery. Her condition later deteriorated into sepsis and encephalopathy prompting endotracheal intubation.

On hospital day 34, an abdominal CT was obtained due to rising white blood cells (32,700/mm3) and elevated lactate (2.3 mmol/L), it showed a loop of the small bowel (15 cm from the ileocecal valve) in the pelvis with apparent stasis [Figure 1]. There was an associated dilation of the short segment, the duodenum, and the stomach concerning for closed-loop obstruction and possible bowel ischemia. Exploratory laparotomy was considered potentially fatal given the patient's unstable condition. Following surrogate consent, a CEUS-CT fusion exam was performed, as part of an ongoing clinical trial, to evaluate for bowel ischemia. Following ultrasound-CT registration, CEUS was performed using a bolus intravenous injection of ultrasound contrast agent (0.4 ml Definity, Lantheus Medical Imaging, N. Billerica MA) during nonlinear contrast imaging mode on a Logiq E10 ultrasound scanner with C1-6 probe (GE Healthcare, Milwaukee WI). Fused CEUS-CT images [Figure 2] revealed a rapid enhancement pattern in the small bowel wall excluding bowel malperfusion and ischemia. Second contrast injection was performed (without CT fusion) approximately 10 min following the initial injection to reevaluate the loop identified on CT fusion while also scanning for pan-ischemia [Figure 2]. Prompt enhancement of the bowel wall relative to the surrounding subcutaneous tissue was again seen, ruling out bowel malperfusion. Her clinical course improved over the next several days with antibiotics and intravenous fluids. A repeat CT of her abdomen was obtained 2 days later which showed nonspecific nondilated fluid-filled small bowel with no evidence of obstruction [Figure 1].
Figure 1: Abdominal computed tomography scans depicting the suspected bowel obstruction before and after its resolution. Top panel scan is notable for a loop of small bowel in the pelvis with dilation of the short segment measuring 3.23 cm (arrow). Bottom panel scan was obtained 2 days postcontrast-enhanced ultrasound, it demonstrates nondilated small bowel (solid white arrow) after the suspected obstruction has subsided

Click here to view
Figure 2: Top panel (a) Shows B-mode ultrasound (left) with contrast-enhanced ultrasound (right) 36 s postcontrast injection where bowel wall enhancement can be observed (white arrows). Bottom panel (b) Shows contrast-enhanced ultrasound (left) with computed tomography (right) fusion where simultaneous bowel wall (white arrow) and subcutaneous tissue (yellow arrow) enhancement is seen

Click here to view



   Discussion Top


Small bowel ischemia remains a challenging diagnosis, especially in critically ill patients. This case report describes the capability of CEUS with CT fusion in ruling out small bowel ischemia in patients with small bowel obstruction. At present, CECT is the diagnostic study of choice in most cases. It can detect conspicuous signs of small bowel ischemia or its complications.[2] CECT has a sensitivity of 89% but suffers from a lower specificity of 67%.[3] Despite including clinical examination and laboratory tests, only 32% of patients are accurately diagnosed before surgical exploration.[4]

Ultrasound is readily available at the bedside and does not involve ionizing radiation. Ultrasound contrast agents are approved by the United States Food and Drug Administration for heart and liver imaging, but can be used off-label for multiple applications like cross-sectional contrast agents.[5] They are safe in patients with renal and hepatic insufficiency and provide real-time visualization of the vasculature in tissues with higher temporal resolution than CT and MRI.[6] Previously, CEUS has been used to quantify the hyperemia of the bowel wall in Crohn's disease.[7] However, it has been scarcely explored to evaluate small bowel ischemia.[8],[9] CEUS can dynamically visualize the vascularity of the bowel wall and the enhancement pattern can be classified relative to the surrounding subcutaneous tissue. We categorized bowel wall enhancement as rapid enhancement, delayed enhancement, or no enhancement. Rapid enhancement rules out bowel malperfusion. Delayed/no enhancement would prompt surgical exploration as malperfusion cannot be excluded.[10]

Localization of a specific bowel segment can be challenging on ultrasound. To confidently identify and evaluate the area of concern, CT fusion was used. When utilized, CEUS can exclude small bowel ischemia and avoid surgical exploration which could be fatal in critically ill patients. In conclusion, CEUS can be employed as a rapid bedside exam to exclude small bowel ischemia in critically ill patients without the risk of surgical exploration.

Declaration of patient consent

The authors certify that they have obtained all appropriate patient consent forms. In the form the patient has given her consent for his images and other clinical information to be reported in the journal. The patient understands that her name and initials will not be published and due efforts will be made to conceal her identity, but anonymity cannot be guaranteed.

Research quality and ethics statement

The authors followed applicable EQUATOR Network (http://www.equator-network.org/) guidelines, notably the CARE guideline, during the conduct of this report.

Financial support and sponsorship

The ultrasound contrast agent used in this study was provided by Lantheus Medical Imaging (N. Billerica, MA).

Conflicts of interest

There are no conflicts of interest.



 
   References Top

1.
Schwarze V, Rübenthaler J, Marschner C, Fabritius MP, Rueckel J, Fink N, et al. Advanced fusion imaging and contrast-enhanced imaging (CT/MRI-CEUS) in oncology. Cancers (Basel) 2020;12:2821.  Back to cited text no. 1
    
2.
Olson MC, Fletcher JG, Nagpal P, Froemming AT, Khandelwal A. Mesenteric ischemia: What the radiologist needs to know. Cardiovasc Diagn Ther 2019;9:S74-87.  Back to cited text no. 2
    
3.
Blachar A, Barnes S, Adam SZ, Levy G, Weinstein I, Precel R, et al. Radiologists' performance in the diagnosis of acute intestinal ischemia, using MDCT and specific CT findings, using a variety of CT protocols. Emerg Radiol 2011;18:385-94.  Back to cited text no. 3
    
4.
Mamode N, Pickford I, Leiberman P. Failure to improve outcome in acute mesenteric ischaemia: Seven-year review. Eur J Surg 1999;165:203-8.  Back to cited text no. 4
    
5.
Gummadi S, Eisenbrey JR, Lyshchik A. Contrast-enhanced ultrasonography in interventional oncology. Abdom Radiol (NY) 2018;43:3166-75.  Back to cited text no. 5
    
6.
Lyshchick A. Specialty Imaging: Fundamentals of CEUS E-Book. Philadelphia, PA: Elsevier Health Sciences; 2019.  Back to cited text no. 6
    
7.
Medellin A, Merrill C, Wilson SR. Role of contrast-enhanced ultrasound in evaluation of the bowel. Abdom Radiol (NY) 2018;43:918-33.  Back to cited text no. 7
    
8.
Hamada T, Yamauchi M, Tanaka M, Hashimoto Y, Nakai K, Suenaga K. Prospective evaluation of contrast-enhanced ultrasonography with advanced dynamic flow for the diagnosis of intestinal ischaemia. Br J Radiol 2007;80:603-8.  Back to cited text no. 8
    
9.
Hata J, Kamada T, Haruma K, Kusunoki H. Evaluation of bowel ischemia with contrast-enhanced US: Initial experience. Radiology 2005;236:712-5.  Back to cited text no. 9
    
10.
Gummadi S, Koenig G, Wessner CE, Machado P, Stem J, Forsberg F, et al. Contrast-enhanced ultrasound in small intestinal ischemia: Proof of concept. J Ultrasound Med 2021. doi: 10.1002/jum.15763. Epub ahead of print.  Back to cited text no. 10
    

Top
Correspondence Address:
Dr. George Koenig
MOB, 7th Floor, 1100 Walnut St., Philadelphia, PA 19107
USA
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jets.jets_57_21

Rights and Permissions


    Figures

  [Figure 1], [Figure 2]



 

Top
  
 
  Search
 
  
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
    Email Alert *
    Add to My List *
* Registration required (free)  


    Abstract
   Introduction
   Case Report
   Discussion
    References
    Article Figures

 Article Access Statistics
    Viewed426    
    Printed2    
    Emailed0    
    PDF Downloaded42    
    Comments [Add]    

Recommend this journal